Symphony Spare Parts Price List PDF

‘Symphony Jumbo Spare Parts Price List’ PDF Quick download link is given at the bottom of this article. You can see the PDF demo, size of the PDF, page numbers, and direct download Free PDF of ‘Symphony spare Parts’ using the download button.

Symphony Spare Parts Price List PDF Free Download

Symphony Cooler Spare Parts

Symphony cooler spare parts price list pdf details are available here. Symphony cooler is a powerful and affordable air cooler in India and is used in lots of houses.

Here is the price list chart of Symphony.

Symphony Cooler Spare Parts Price List

Symphony Cooler Spare PartsPrice List
HAVAI SYNCHRONOUS SWING MOTORRs. 329/-
HAVAI SUBMERSIBLE COOLER PUMP Rs. 449/-
MAIN/ELECTRIC MOTORRs. 1680/-
HAVAI COOLER PERFUMERs. 599/-
HAVAI HONEYCOMB PADRs. 615/-
HAVAI THREE-PIN POWERCHORDRs. 399/-
HAVAI THREE-PIN POWER CHORDRs. 249/-
HAVAI PREMIUM COVER FOR SYMPHONY DIET 3DRs. 949/-
HAVAI FLEXIBLE PIPE ROLLRs. 249/-
HAVAI SUBMERSIBLE COOLER PUMPRs. 599/-

How Does a Central Air Conditioner Work

Although central air conditioners differ from model to model. They operate on similar principles.

Here we will address how central air conditioners work as well as potential problems you may encounter included among the components that make up a central air system is a condensing unit which is located outside the home.

The condensing unit contains the air conditioner condenser coils the compressor and the condenser fan motor the evaporator coils or cooling coils are located inside the home and are mounted on top of a furnace or air handler.

The furnace or air handler uses a circulation blower fan to draw air through the returned vent blow.

It passes the evaporator coils and forces the air through the homes venting the room air is then drawn back through the returned and the airflow cycle continues once the room air has cooled sufficiently to the wall thermostat signals.

The circulation blower fan and a condensing unit are to be turned off until the room temperature increases.

This process can be broken down into three main factors temperature control cooling and air circulation.

The temperature in the home is regulated by the wall thermostat the thermostat can be powered by the furnace control board or by batteries.

The thermostat must be in a central location in the home positioned at eye level and away from direct sunlight for proper temperature regulation when the thermostat detects an increase in temperature it closes the cooling circuit allowing voltage to travel to the control board.

The control board uses a time sequence to send 120 volts of alternating current to the circulation blower fan motor in the furnace and 24 volts to the condensing unit contactor when the condensing unit contactor is energized it allows 240 volts to flow through a nearby disconnect box to the compressor and condenser fan motor.

The disconnect box which provides a way to turn off power to the condensing unit outside includes a cartridge that may contain fuses if the compressor and condenser fan motor fail to work the disconnect box fuses can be tested for continuity to determine.

If a continuous electrical path is present the compressor acts as a pump compressing refrigerant in gas form into the condenser coils where the gas is condensed into a hot liquid.

The condenser coils dissipate the heat as the liquid travels through them and a fan is used to assist the coils.

In this process once the refrigerant has passed through the condenser coils it travels to the evaporator coils located on the furnace or air handler as the refrigerant liquid enters the coils it expands into a gas which makes the coils cold.

The gas flows through the coils to a suction line attached to the compressor converts.

The gas back into a liquid and the cooling cycle continues the humidity in the air condenses on the cold evaporator coils and drips down into a set of collection trays.

The trays are attached to either a condensate pump or a floor drain. It’s important to keep the condenser clean if leaves or other debris clog the coils. The heat will not be dissipated properly and the system will not function efficiently.

You can use a garden hose to clean the condenser by spraying the coils from the inside out. The most important factor in efficient operation is air flow to ensure proper airflow.

The air filter should be checked monthly and replaced as needed there are several types of filters available and range from 1 to 5 inches thick.

The filter can be installed into the slot in the return or in an air cleaner some homes will have an electronic air filter which is powered by the furnace or air handler control board.

When the circulation blower fan turns on the blower fan motor can run at multiple speeds to improve efficiency lower speeds are used.

When the furnace is heating higher speeds are used for air conditioning.

If the circulation blower fan becomes noisy during use the set screw on the blower wheel may have loosened causing the wheel to wobble on the motor shaft.

You can fix this problem by tightening or replacing the screw or replacing the blower wheel altogether repair clinic has a solution for many of the problems you may be experiencing with your central air system to find a complete list of compatible parts.

The condensing unit and furnace will have separate model numbers to find parts such as the circulation blower fan motor or control board you will need to enter the furnace model number to find a contractor or condenser fan motor.

Author
Language English
No. of Pages63
PDF Size4 MB
CategoryList
Source/Creditswww.bhimappdownload.in

Related PDFs

IRCTC Pantry Car Price List 2023 PDF

Symphony Spare Parts Price List PDF Free Download

Leave a Comment

Your email address will not be published. Required fields are marked *

error: Content is protected !!